หมวดหมู่ : INSTRUMENTS ,  TOKYO KEISO ,  Flow Measurement ,  Ultrasonic Flowmeters for Built-in Use , 
แบรนด์ : TOKYO KEISO
Share
Features
Applications
Short Specifications
Model | UCM-04A | UCM-06A | UCUF-04M (UCM Version) + UCM-04A-SP |
---|---|---|---|
Measuring fluids | Liquid general (exclude liquids with bubbles and permeable liquids) | ||
Flow range | Max.: 0 to 3.0 L/min Min.: 0 to 0.2 L/min | Max.: 0 to 8.0 L/min Min.: 0 to 0.4 L/min | Max.: 0 to 3.0 L/min Min.: 0 to 0.2 L/min |
Fluid sonic range | 1000 to 2200 m/s | ||
Fluid kinetic viscosity | 0.3 to 40mm²/s | ||
Fluid temperature | 10 to 60°C | ||
Fluid pressure | 0 to 0.4 MPa | ||
Material |
| Detector Body: PFA Tube: PFA Sensor cover: PP Cable fitting: PP Cable sheath: PTFE Sensor cap: PFA Jacket: PVDF | |
Converter
| |||
Process connection | PFA Tube ends | ||
Connection size | 6.35OD x 4.35ID tube | 9.53OD x 6.35ID tube | 6.35OD x 4.35ID tube |
Current output | 4 to 20 mA DC, 0 to 20 mA DC | ||
Accuracy | ±1% F.S. for analog output when flow velocity 1m/s or more | ||
Alarm output | NPN open collector ,1 contact (high or low), 30 VDC,20mA or less | ||
Low cut-off | 0 to 30% of F.S. | ||
Dumping | 0s,0.2s,0.5s,1s,2s,3s,5s,10s | ||
Status indication | By 7 segments display | ||
Commnication | Modbus protocol RS-485 Half duplex asynchronous, Baud rate 19200 bps, Multi drop Max. 32(Addresses are set by configuration software) | ||
Power supply | 24V DC± 10%, Consumption approx. 80mA | ||
Cable | 5m of dedicated cable is attached as an accessory. 10m cable is optional. | ||
Enclosure | Equivalent to IP64 (indoor use) |