Measuring object | Liquids, Gases, Saturated steam |
---|
Flow Range | - Water:
- Max. 0 to 119.73 m³/h (100A, at 20°C)
Min. 0 to 5.51 m³/h (25A, at 20°C) - Air:
- ax. 0 to 10385 m³/h(nor) (100A, at 0°C,0.99MPa)
Min. 0 to 77m³/h(nor) (25A, at 0°C,0MPa) - Saturated steam:
- Max. 0 to 10745 kg/h (100A, at1.6MPA)
Min. 0 to 103 kg/h (25A, at0.1MPA)
|
---|
Guaranteed Accuracy Range | Max. Rangeability: 1:14 |
---|
Fluid Pressure | Liquids: -98kPa to 2MPa Gases: -98kPa to 1MPa Saturated steam: -98kPa to 1.6MPa |
---|
Fluid Temperature | Liquids: -20°C to 120°C Gases: -20°C to 120°C Saturated steam: Max.204.3 °C |
---|
Connection | Wafer |
---|
Connection Rating | JIS10K/20K,ANSI Class150/300,DIN PN16/40,GB PN1.6/4.0 |
---|
Connection (Meter) Size | 25, 40, 50, 65, 80, 100(mm) 1, 1-1/2, 2, 2-1/2, 3, 4(inch) |
---|
Materials | - Detector:
- Body: SCS14A
Cone: SUS316 H-Connector: SUS316/SCS14 Oval flange gasket: PTFE - 3Way cock piece:
- Body: SCS14A
O-ring: Gasket PTFE and Fluorocarbon rubber Ethylene propylene rubber is also available. - Differential transmitter:
- It depends on a model
|
---|
Series /Power supply /Output | - VTG Series:
- Differential transmitter is provided by others.
- VTF Series:
- FCX-AIII (Model FKC) differential pressure transmitter made by Fuji Electric Co. is installed in this series.
16.1 to 45 VDC / 2wire 4-20mADC(Non explosionproof or Flameproof by TIIS) - VTM Series:
- EDR-N7C differential pressure transmitter made by Hitachi High-Tech Control Systems Co. is installed in this series.
11.4 to 42 VDC / 2wire 4-20mADC(Non explosionproof or Flameproof by TIIS) This instrument is used for the mass flow measurement of gas and saturated steam.
|
---|
Accuracy | ±1.0 to 1.5 %(F.S.) |
---|