หมวดหมู่ : INSTRUMENTS ,  TOKYO KEISO ,  Flow Measurement ,  Thermal Mass Flowmeters and Controllers , 
แบรนด์ : TOKYO KEISO
Share
Recommended Applications
Short Specifications
Measuring fluid | All kinds of gases, except gases containing more than 10%(Vol) of H2 or He and mixtures of H2 or He and CnHm |
---|---|
Flow range | Max. 0 to 500 L/min (nor) Min. 0 to 2 L/min (nor) |
Fluid Temperature | 5 to 50°C |
Fluid Pressure | Max. 0.98 MPa |
Flow control range | 2 to 100 % of full scale. |
Control DP range | 0.06 to 0.3MPa or 0.18 to 0.44MPa (Refer to Technical Guidance for the details.) |
Control accuracy | ± 2% F.S. (at 25°C) |
Response | 2 or 4 sec. (90%) |
Material |
|
Process connection | 1/4, 3/4, 1 Rc thread, OD 1/4 SW, VCR, VCO, etc. |
Output / Power supply | DC 4 to 20mA / DC 21 to 27V 330mA DC 0 to 5V / DC ±15V -200 +150mA |
Recommended Electronics | TM-1400 Mini Convertor Unit |