หมวดหมู่ : INSTRUMENTS ,  TOKYO KEISO ,  Flow Measurement ,  Thermal Flowmeters , 
แบรนด์ : TOKYO KEISO
Share
Features
Applications
Short Specifications
Future /Type | Insertion type for large pipe sizes Integral type / Separate type | Inline type for medium pipe sizes Integral type / Separate type | Inline type for small pipe sizes Integral type / Separate type | Variable length insertion type |
---|---|---|---|---|
Model | SRT1100 | SRT1200 | SRT1300 | SRT1400 |
View | ||||
Measuring object | Non-corrosive gases | |||
Process connection | Flange JIS 10K/20K, ANSI 150/300, JPI 150/300 Insertion type by tube fitting Outside diameter 20 mm SWL, VCR, Rc 3/8", 1/2", 3/4", 1" Wafer 40 to 150 mm | |||
Meter size | 50A to 1500A | 40A to 150A | 10A to 25A | 50A to 900A |
Fluid temperature | -20 to 120℃ | |||
Pressure | 1 MPa Max. | |||
Flow range | Air/N₂ Max.: 35600 to 891700m³/h(nor) Min.: 63 to 1200 m³/h(nor) | Air/N₂ Max.: 425 to 10600 m³/h(nor) Min.: 50 to 780m³/h(nor) | Air/N₂ Max.: 33 to 330 m³/h(nor) Min.: 6.0 to 60 m³/h(nor) | Air/N₂ Max.: 12840 to 321000 m³/h(nor) Min.: 63 to 1200 m³/h(nor) |
Material contacting gases | SUS316L, SUS316, SCS14 Sensor element is made of SUS316L | |||
Power supply | 24±10% VDC | |||
Protection class | IP65 |