CAPATIC (CA-1000, CA-1000S)

คุณสมบัติสินค้า:

Capacitance type level switches

แบรนด์ : TOKYO KEISO

Share

Features

  • Low cost, compared with float, ultrasonic and pressure sensor type level switches.
  • Both conductive and non-conductive liquids can be detected.
  • No moving parts offers long term operation
  • The action point can be set by adjusting the rotative trimmers. Special instruments and tools are not needed.
  • Besides weatherproof type, intrinsically safe type is also available.

 

Short Specifications

TypeNon-explosionproof type
Electrode and transmitter
integrated type
CA-1XXXW
Intrinsically safe type
Electrode and transmitter
separated type
CA-1XXXS
Appearance
Measuring object
Liquid: 
Level: 
Liquid of which dielectric constant is more than 2, and which is conductive or non conductive
Two liquids interface: 
Difference of the dielectric constants to be more than 10 times
Dielectric constant of lower liquid should be larger than upper liquid, and the thickness of upper liquid shoud be constant.
Powder or solids: 
Study about the use condition is needed.
(Please consult us.)
Op. temperature-10 to 80°C Bare and PFA covered(PTFE insulator), without fin
80 to 180°C Bare and PFA covered(PTFE insulator), with fin
180 to 300°C Bare (matallic)(Ceramic insulator), with fin
Op. pressureMax. 1MPa
Material
Earthed and detecting electrodes: 
SUS304 (Option: SUS316,SUS316L)
Insulator: 
PTFE (Option: Ceramics)
Seal: 
FKM (Option: NBR, VMQ, Karletz)
Flange: 
SUS304 (Option: SUS316, SUS316L)
Process connection1 B, JIS 10 K FF Flange
OutputSPDT Relay contact
Power supply95 to 115 V AC or
190 to 230 V AC, 50/60 Hz
100 V AC or 200 V AC, 50/60 Hz
Consumption6 VA
ConstructionEquiv. to IP 54TIIS i3aG4