Measuring fluid | Liquids, gases, steam |
---|
Flow range | - Liquids:
- Water
Max.15 to 150m³/h Min. 0.01 to 0.1m³/h - Gases:
- Max. 450 to 4500m³/h(nor)
Min. 0.292 to 2.92m³/h(nor)
|
---|
Size | Meter size 15mm(1/2") to 150(6")mm |
---|
Meter size | Carbon steel, SUS304, SUS316, SUS316L Rubber Lining, Fluorocarbon resin Lining, PVC Lining, Glass Lining |
---|
Fluid temperature | - Metallic material General purpose:
- Max.149°C
Available up to 250°C on request - Jacketed version:
- 300°C
Available up to 400°C on request - Lining material:
- Rubber Lining:
- -10 to 80°C
- Fluorocarbon resin Lining:
- -10 to 80°C
- PVC Lining:
- 0 to 60°C
- Glass Lining:
- -10 to 110°C
|
---|
Fluid pressure | - 150lbs(10K)class:
- Max. 1.4MPa(Up to 120°C)
Max. 1.2MPa(Up to 220°C) Min. 1.0MPa(Up to 300°C) - 300lbs(20K)class:
- Max. 3.4MPa(Up to 120°C)
Max. 3.1MPa(Up to 220°C) Max. 2.9MPa(Up to 300°C) Max. 2.6MPa(Up to 350°C) Max. 2.3MPa(Up to 400°C) On request High pressure up to 200MPa for the specifications of higher rpressure model. |
---|
Connection size | 10k class: 15A to 150A JIS10kFF, ANSI#150, DIN#300 flange connection 20k class: 15A to 150A JIS20kRF, ANSI#300, DIN#300 flange connection Screw connection |
---|
Rangeability | 10 : 1 |
---|
Indication accuracy | ± 1.5% F.S. (±2% F.S. for resin material float version), (Opton: ±1.0% F.S. Consult factory) |
---|
Functions /construction | - AM-140□:
- Local indication / Dust-and splash-proof IP54 equivalent
- AM-131□:
- Local indication + Pneumatic transmission /
Dust-and splash-proof IP54 equivalent - AM-152□:
- Local indication + Electric transmission /
Dust-and splash-proof IP54 equivalent - EP-AM-152□:
- Local indication + Electric transmission /
Flame proof Exd IIBT4(Ambient temp: -20 to +55°C) - AM-169□:
- Local indication + Local integration + Pulse output /
Dust-and splash-proof IP54 equivalent - EP-AM-169□:
- Local indication + Local integration + Pulse output /
Flame proof d2G4(Ambient temp: -20 to +55°C) - AM-174□:
- Local indication + Alarm output / Dust-and splash-proof IP54 equivalent
- EP-AM-174□:
- Local indication + Alarm output /
Flame proof d2G4(Ambient temp: -10 to +60°C) - S-AM-174□:
- Local indication + Alarm output /
Intrinsically safe Exia IICT6(Ambient temp: -10 to +60°C) supplied with safety barrier EB3C
|
---|