TGR4500

คุณสมบัติสินค้า:

Micropulse level meters

หมวดหมู่ : INSTRUMENTS TOKYO KEISO Level Measurement Level Gauges

แบรนด์ : TOKYO KEISO

Share

Features

  • Micro-pulse achieves high accuracy regardless of the temperature and pressure change, vapor and dust of the tank
  • Density or temperature change of measuring liquid will not affect the measuring accuracy
  • Easy change of the basic settings and confirmation of the identifying value, with the display unit
  • Non-moving parts guarantee maintenance-free operation
  • Thanks to the 2-wire loop powered system, reduction of cable and installation cost are possible
  • Thanks to the 2-wire loop powered system, revamp from other devices is also available easily
  • The device is delivered with factory setting, and therefore no need for field calibration

 

Short Specifications

Measuring
object
Liquids
Probe typeTGR4511
Single rod probe
TGR4521
Single cable probe
TGR4522
Twin cable probe
TGR4531
Coaxial probe
Probe length
(Maximum)
3m24m24m3m
Probe diameterφ8mmφ4mmφ4mmφ28mm
Probe materialStainless steel (SS316)Stainless steel
(SS316),
FEP coated probe
Stainless steel
(SS316),
FEP (Spacer)
Stainless steel (SS316),
PTFE (Spacer)
Process
connection
G1" Male screw
1" NPT Male screw
G1-1/2" Male screw
1-1/2" NPT Male screw
G1" Male screw
1" NPT Male screw
Dielectric
constant
>2.3>2.3>1.8>1.5
Product
temperature
–30 to 200°C–30 to 150°C
(However, care about process connection temperature)
Operating
pressure
Maximum 4 MPa
AccuracyMeasurement distance < 15 m: ± 15 mm + 0.01% FS
Measurement distance ≥ 15 m: ± 0.1% of Reading + 0.01% FS
Based on a basal condition
OutputDC4 to 20 mA (HART)
Power supply2-wire loop powered system
Rated voltage: DC 24 V
Voltage range: DC 18 to 35 V (Standard type), DC 18 to 28 V (Explosion proof type)
HousingAluminium alloy
Protection
class
· IP65 (IEC 60529 / JIS C0920)

· Explosion proof specification
ATEX: 
II 1G Ex ia IIC T6…T3
II 1G Ex ia IIB T6…T3
(IIB is applied for the probe coated by FEP)
When using this model at the hazardous area as in intrinsically safe circuit,
the safety barrier shall be used in the non-hazardous area in 2 line loop.