O-1000

คุณสมบัติสินค้า:

แบรนด์ : TOKYO KEISO

Share

Features

  • Economical measurement even for large size lines.
  • Any flow direction of horizontal, vertical including top to bottom possible
  • High press. and temp. acceptable thanks to metal tube flowmeter
  • No Utility supply needed for local indication.
  • Alarm contact(s), Analog output or Totalaizer are optionally available

 

Short Specifications

Measuring fluidLiquids(Viscosity: up to 3mPa·s) and Gases
(Not suitable for slurry and steam)
Flow rangeLiquids(in case of density: 1.0g/cm³ and viscosity: 1.0mPa·s)
Max.600 to 3000m³/h (Size: 500mm, at DP=60kPa)
Min.1 to 5m³/h (Size: 50mm, at DP=60kPa)

Gases(in case of temperature: 0°C and pressure: 0MPa)
Max. 14000 to 70000m³/h(nor) (Size: 500mm, at DP=60kPa)
Min. 20 to 100m³/h(nor) (Size: 50mm, at DP= 10kPa)
Fluid temperature-20 to 200°C
Fluid pressureMax. 1.4MPa(In case of liquid temperature of 120°C or less)
Max. 1.2MPa(In case of liquid temperature of more than 120°C to 200°C)
Type of tapping
and available size
1D·1/2D taps: 
100A(4B) to 500A(20B)
Corner(Ring) taps: 
50A(2B) to 500A(20B)
Flange taps: 
50A(2B) to 500A(20B)
Vena contradta taps: 
100A(4B) to 500A(20B)
Material
Main orifice: 
SUS304, SUS316
Orifice ring: 
SS400, SUS304, SUS316
Ball valve: 
C3771BE, SCS14A
Bypass piping: 
SGP, SUS304, SUS316
Bypass orifice: 
SUS304, SUS316
Gasket: 
Non Asbestos (for liquids)
NBR or FPM (for gases)
Flowmeter: 
SS400/SU304, SUS304 or SUS316
Indication accuracy±3%F.S.
Function/
Construction
O-140□-□□: 
Local indication / Weather proof IP54 equivalent
O-131□-□□: 
Local indication + Pneumatic transmission / Weather proof IP54 equivalent
O-152□-□□: 
Local indication + Electric transmission / Weather proof IP54 equivalent
EP-O-152□-□□: 
Local indication + Electric transmission /Flame proof Exd IIBT4 (Ambient temp: -20 to +55°C)
O-169□-□□: 
Local indication + Local integration + Pulse output / Weather proof IP54 equivalent
EP-O-169□-□□: 
Local indication + Local integration + Pulse output / Flame proof d2G4
(Ambient temp: -20 to +55°C)
O-174□-□□: 
Local indication + Alarm output / Weather proof IP54 equivalent
EP-O-174□-□□: 
Local indication + Alarm output / Flame proof d2G4
(Ambient temp: -10 to +60°C)
IS-O-174□-□□: 
Local indication + Alarm output / Intrinsically safe Exia IICT6
(Ambient temp: -10 to +60°C)
supplied with safety barrier EB3C


สินค้าเกี่ยวข้อง

Powered by MakeWebEasy.com